PD-58 Technical Data

Distance

measurements:

Measuring accuracy

up to 10 m

(2 σ, standard deviation)

typically: ± 1.5 mm*

Power Range

Technology™:

Range (use target plate

from about 80m)

0.05 m to 100 m

Smallest unit displayed

1mm

Distance measurement

Available

Minimum/maximum

measurement, Continuous

measurement

Available

Area/volume calculation of

room data

Available

Addition / subtraction

Available

Indirect measurement

using Pythagoras

Available

Tilt measurements:

Tilt sensor:

Accuracy

(2 σ, standard deviation)

- to laser beam

- to the housing

 

 

 

 

± 0.3°

± 0.3°

Horizontal measurement

Available

Indirect measurement

using tilt sensor (direct

horizontal distance)

Available

Angle measurement using

tilt sensor(± 45°)

Available

General:

Laser class

II

Laser type

635 nm, < 1 mW

 laser point

(at distances)

6 / 30 / 60 mm

(10 / 50 / 100 m)

Autom. laser switch-off

after 3 min

Autom. instrument switch off

after 6 min

Display illumination

Available

Keypad illumination

Available

Multifunctional end piece

Available

Timer (self-triggering)

Available

Save constant value

Available

Historical storage

(20 values)

Available

Tripod thread

Available

Battery life,

Type AAA, 2 x 1.5V

up to

5 000 measurements

Protection against

splashes and dust

IP 54, dust-proof,

splash-proof

Dimensions

 

Weight (with batteries)

 

Temperature range:

Storage

 

Operation

 

-25°C up to +70°C

(-13°F up to +158°F)

 

-10°C up to +50°C

(14°F up to +122°F)

 

* maximum deviation occurs under unfavourable conditions such

as bright sunlight or when measuring to poorly reflecting or very

rough surfaces. Measuring accuracy between 10 m and 30 m may

deteriorate to approx. ± 0.025 mm/m, for distances above 30 m

to ± 0.1 mm/m.

  